Operators Manual
Section 4-25
NOTE:
As a check to determine whether the failsafe switch or
the travel distance counter is reversing the machine, use
the following steps:
1.
Once the operator has pressed the Start Key (but not
the button on the handle), press the
Monitor
key.
2.
The keypad display will change and display the
Pindeck Distance
in the lower left corner and the
Failsafe Distance
in the lower right corner.
Operate the machine down the lane. Check the keypad display
as the machine is returning to the foul line. The setting
that "tripped" will display "
0
" indicating that this
distance was met. Once the machine reaches the foul line
this display will switch back to normal display.
A diagram in Section 5 shows the proper location of the
machine when it stops in the pindeck. Refer to this drawing
to confirm the correct End Cleaning Distance. To change the
display back to the Operators Menu, press the
Monitor
key
once again.
If the numbers shown are correct, depress the
NEXT
key.
The following prompt will appear:
SPRAY ON TIME
04 IN TENTHS 04
This prompt, along with the two numbers displayed, is
referring to the amount of time for the spray to be "ON"
each time cleaning solution is sprayed. (NOTE: The number
shown refers to "tenths" of seconds. For example, "04" is
actually 0.4 seconds.)
To change the time, use the UP or DOWN arrow keys.
Once again, the right side number will change. When the
correct number is reached, depress ENTER and both numbers
will display the new "Spray On Time".