4.7
Ethernet
The standard version of the KeTop is equipped with an Ethernet interface. This
interface is based on the 10BaseT specification and suitable for the half-duplex
mode (the operation with 100Mbit requires a special connection cable).
The data communication for these interfaces takes place via the Ethernet con-
nector S4 (marking: ETHERNET) in the cable entrance area of the KeTop.
The following interface parameters are defined and cannot be changed:
●
10 MBit (100MBit with appropriate cable possible)
●
TCP/IP protocol
The Ethernet interface is selected under Windows CE as follows:
Start
▶
Settings
▶
Control Panel
▶
Network and Dial-up Connections
: Here
you can select the Ethernet on-board interface SMSC911x11.
WARNING!
If the KeTop and the control do not communicate via a point-to-point connec-
tion, it may happen that the keypad data, for example, are transmitted with a
delay.
Therefore it is advisable to establish the connection between the control and
the KeTop only via an Ethernet switch which enables a point-to-point connec-
tion.
The positions of the Dip switches in the cable entrance area are not relevant
for this interface.
Information
The simultaneous use of the Ethernet interface and the COM interface
(RS-422-A or RS-232-C) is only possible with an appropriate cable.