16 Test for chemical resistance
16.1 Test procedure
16.1.1
Test 1
The units under test (UUT) are placed in a closable box (365 x 260 x 200 mm).
A ball of absorbent cotton that was tinctured with approx. 5 ml solvent will be
placed above the UUT. To avoid early evaporation, a cup (250 ml) will be put
over the ball of absorbent cottont.
10 min later the cup and the ball of absorbent cotton will be removed. The
solvent that remains on the UUT will not be wiped off and the box will be closed
immediately afterwards. The UUT will remain in the closed box for at least
24 hours.
The test will be performed at 20°C environmental temperature.
16.1.2
Test 2
The units under test (UUT) are placed in a closable box (365 x 260 x 200 mm).
Approx. 5 ml solvent will be sprayed over the UUT. The box will be closed and
the UUT will remain in the closed box for at least 24 hours.
The test will be performed at 20°C environmental temperature.
16.2 Test results
Substance
Test passed
Problems / no test
cutting oil - test 1
●
LO-Smoke Levex
5047
●
Superfin 100
●
DIE-KOTE 7270-M
●
handle
●
rubber cover over enabling switch
●
type plate
●
keypad
●
blind plug
●
connection cable
●
illuminated push-button
●
key switch
●
emergency stop button
●
display gasket
●
housing gasket
●
cover gasket
●
parts of housing - not tested
●
knob for handwheel - not tested
●
knob for potentiometer - not tested
●
dummy covers - not tested
cutting oil - test 2
●
LO-Smoke Levex
5047
●
Superfin 100
●
DIE-KOTE 7270-M
not tested
Test for chemical resistance
© KEBA 2009
User's Manual V1.50
157