Reverse polarity protection:
Yes
Short circuit and overload protection:
Yes
Operating cycle:
2
nd
position: 10
5
3
rd
position: 5 x 10
4
Actuating force:
from 1
st
position to 2
nd
position: 5 N typically
from 2
nd
position to 3
rd
position: 20 N typically
Data according to EN ISO 13849-1:2008:
Enabling:
Category:
3
Performance Level:
d
Proof Test Interval:
20 years
MTTF
d
symmetrized according to D.2 at
EN ISO 13849-1:
78 years *
PFH
d
: 1.57 x 10
-7
Panic:
Category:
3
Performance Level:
d
Proof Test Interval:
20 years
MTTF
d
symmetrized according to D.2 at
EN ISO 13849-1:
88 years *
PFH
d
: 1.35 x 10
-7
* The monitoring device was not taken into consideration when calculating the
MTTF
d
-values. You can also refer to
chapter 4.5.1.2 "Panic" on page 29
chapter 4.5.2 "Example of Connection with PILZ PNOZ s6.1 Control Relay"
on page 31
13.7 Accessories
Wall bracket:
For stationary operation or storage of the Ke-
Top.
KeTop WB 090: Wall bracket without cable suspension.
KeTop WB 095: Wall bracket with cable suspension.
KeTop WB 110:
Wall bracket with height adjustment and with
cable suspension.
KeTop WB 120:
Wall bracket with cable suspension and sole-
noids.
Connection cable:
Resistent to twisting, bending and foot traf-
fic,with 20-pin push pull connector or 17-pin
circular connector.
KeTop TT025: 2.5 m / 8.2 ft
KeTop TT050: 5 m / 16.4 ft
KeTop TT100: 10 m / 32.8 ft
KeTop TT150: 15 m / 49.2 ft
KeTop TT200: 20 m / 65.6 ft
Intermediate cable:
Connection box to connection cable
KeTop IC220: 2 m / 6.56 ft
Technical data
KeTop T50VGA
© KEBA 2009
User's Manual V1.50
130