10.3.6
Technical data of Junction Box JB 001
10.3.6.1
General data
Nominal supply voltage (KeTop):
24 V DC
Supply voltage range (KeTop):
18 V DC to 32 V DC
Max. interruption time of the supply (KeTop):
≤
10 ms (acc. to EN 61131)
Power consumption:
without KeTop: -
with KeTop: see corresponding KeTop User Manual
Inrush current (KeTop):
see corresponding KeTop User Manual
Safety class:
III in accordance with EN 61131-2 and
EN 50178
10.3.6.2
Environmental conditions
Operating temperature:
5 °C to 55 °C (41 °F to 131 °F)
Storage temperature:
-25 °C to +70 °C (-13 °F to 158 °F)
Relative humidity (non-condensing):
5 % to 95 %
Vibration resistance (operation):
(IEC 60068-2-6)
5 Hz
≤
f < 9 Hz at 7 mm (0.276 in)
9 Hz
≤
f < 150 Hz at 2 g (0.0044 pound)
Shock resistance (operation):
15 g / 11 ms (IEC 60068-2-27)
10.3.6.3
Housing
Construction:
Steel panel housing, blue zinc coated
Withstands grease, oil, lubricants, alcohol, etc.
Flammability class: UL94-V0
Dimensions:
Width: 67.2 mm (2.6457 in)
Height: 76.1 mm (2.9961 in)
Depth: 26 mm (1.0236 in)
Protection degree:
IP20
Weight:
220 g (0.485 lb)
10.4 KeTop CB211 Connection Box
The KeTop CB211 connection box is used for integration of the KeTop in the
machine/system. It is suitable for wall mounting and can also be mounted on
a mounting rail through the use of the mounting rail assembly kit
(KeTop DR200). The KeTop CB211 connection box has the following connec-
tions:
Accessories
KeTop T50VGA
© KEBA 2009
User's Manual V1.50
110
Summary of Contents for KeTop T100
Page 1: ...KEMRO KeTop T50VGA User s Manual V1 50 Translation of the original instructions ...
Page 4: ......
Page 10: ......