MALFUNCTIONS AND MAINTENANCE
- 93 -
Dechlorination Module
WARNING
The housing of the active carbon filter is under pressure!
Observe the following:
1.
Before opening the housing of the active carbon filter, the inlet
ball valve is to be shut.
2.
Open ball valve (62/6) in front of the bottom manometer for a
short period; this releases the pressure in the housing of the acti-
vated carbon filter.
3.
Open the housing of the activated carbon filter.
4.
Remove the used 30"-active carbon filter elements (ten in total)
and replace with new ones.
5.
Mount filter housing together again.
6.
Open intake ball valve again.
Fig. 62
1
Lid lock (open for exchanging the fil-
ter plugs
2
Filter bowl, dechlorination module
3
Pressure gange, intake pressure
4
Sampling valves (also to be used for
pressure compensation) + draining
5
Pressure gange, outlet pressure
6
Sampling valve (also to be used for
pressure compensation) + draining
1
2
3
5
4
6