KAESER KOMPRESSOREN AG
P.O.Box 2143 • 96410 Coburg • Germany • Phone +49 9561 6400
Fax +49 9561 640130
M. Kiesewetter-QA /QESM/F-100714-Performance test by helium - 4 / June 3
rd
, 2013
Frequency
Gas inlet
temperature
Gas suction
pressure
Outlet
pressure
Mass
throughput
Total power
consumption
20 Hz
299,1 K
1,05 bar (abs)
14 bar
29,72 g/s
108,2 kW
40 Hz
300,5 K
1,05 bar (abs)
14 bar
61,72 g/s
197,3 kW
50 Hz
301,2 K
1,05 bar (abs)
14 bar
77,25 g/s
246,5 kW
Comments:
We confirm that the package/part meets the order requirements.
Coburg, 19.09.2013
(manufacturer’s competent examiner)
Summary of Contents for ESD 352 SFC
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 171: ...KKW SSC 2 03 en 01 BA SIGMA CONTROL FLUID KKW SSC 2 03 01 20130805 113302...
Page 173: ......
Page 175: ...Contents ii Quick user guide Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03 USE...
Page 215: ...Contents iv Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Page 392: ...KKW GBASE 1 00 en ERSATZTEILE 10357405_10 ESD 2C 20130903 115349...