Alarm
Possible cause
Remedy
Cooling oil leaking into the floor
pan.
Hose coupling or maintenance
hose still plugged into the
quick-release coupling on the
oil separator tank.
Remove coupling or mainte‐
nance hose.
Oil cooler leaking.
Contact KAESERservice.
Leaking joints.
Tighten joints.
Replace seals.
Cooling oil consumption too
high.
Unsuitable oil is being used.
Use recommended cooling oil.
Oil separator cartridge split.
Change the oil separator car‐
tridge.
Oil level in the oil separator
tank too high.
Drain off oil until the correct lev‐
el is reached.
Oil return line clogged.
Check dirt trap in the return
line.
Tab. 36 Other faults and actions.
9
Fault Recognition and Rectification
9.2
Other faults
54
Service Manual Screw Compressor
ESD 442/14 bar (abs) SFC SIGMA CONTROL 2
ESD_2C_10357405_10–LIN_00 E
Summary of Contents for ESD 352 SFC
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 171: ...KKW SSC 2 03 en 01 BA SIGMA CONTROL FLUID KKW SSC 2 03 01 20130805 113302...
Page 173: ......
Page 175: ...Contents ii Quick user guide Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03 USE...
Page 215: ...Contents iv Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Page 392: ...KKW GBASE 1 00 en ERSATZTEILE 10357405_10 ESD 2C 20130903 115349...