11 Safety relief valve checking
Overview
■ Preparing the test
■ Performing the test
■ Correct conclusion of the test
■ Resetting
When the check mode is activated, monitoring of internal pressure (blow-off protection – if
provided) and regulation of network pressure are deactivated.
The measured value of internal pressure pi is used to describe the following check.
Check box
Status
☑
activated
☐
deactivated
Tab. 3 Check box status
Danger of injury from pressurized components!
➤ Perform the following actions in the sequence provided.
Preparing the test
1. Note the activating pressure of the safety relief valve from the machine's nameplate.
2. Press the «OFF» key to shut down the machine.
3. Close the user's shut-off valve between the machine and the air distribution network.
4. Log on to SIGMA CONTROL 2 with access level 2 (see chapter 7.2.6).
5. In operating mode, switch to the main menu with the «Enter» key.
6. Select the
< Machine test ➙ TÜV inspection > menu.
Safety relief valve is displayed as an active line.
8 9 p s i 0 8 : 1 5 1 7 6 ° F
9.1 TÜV inspection
Menu
Safety valve: ☐
Active line with check box
pRV: 232 psi¦ pi 0 psi
Relief valve activating pressure (example)
Reset: ☐
·········
Performing the test
1. Press «Enter».
The
check box flashes in the active line.
2. Use the «UP» key to activate the check box.
11 Safety relief valve checking
9_9450 03 USE
Quick user guide Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
17
Summary of Contents for ESD 352 SFC
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 171: ...KKW SSC 2 03 en 01 BA SIGMA CONTROL FLUID KKW SSC 2 03 01 20130805 113302...
Page 173: ......
Page 175: ...Contents ii Quick user guide Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03 USE...
Page 215: ...Contents iv Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Page 392: ...KKW GBASE 1 00 en ERSATZTEILE 10357405_10 ESD 2C 20130903 115349...