12 Checking the temperature sensor and overheating
shutdown function
The machine should shut down if the airend discharge temperature (ADT) reaches a maximum of
230°F.
SIGMA CONTROL 2 will simulate a higher temperature for checking this function.
For this purpose, SIGMA CONTROL 2 automatically determines an offset value to be displayed.
During the test mode, this offset is added to the actual airend discharge temperature to cause the
machine to shut down prematurely.
In standard operation, SIGMA CONTROL 2 generates the "overtemperature" fault message when
the maximum airend discharge temperature is reached. Since the modified test temperature is 2 K
below the fault message switching point for overtemperature, the system will not generate a fault
message in test mode.
Overview
■ Shut down the machine and allow to cool down slightly
■ Performing the test
■ Correct conclusion of the test
■ Resetting
Performing the test
Precondition Machine has cooled down approximately 40°F.
1. Log on to SIGMA CONTROL 2 with access level 2. (see section 7.2.6).
2. In operating mode, switch to the main menu with the «Enter» key.
3. Select the
< Machine test ➙ TÜV inspection > menu.
Pressure relief valve is displayed in the active line.
4. Press «DOWN» repeatedly until
Airend discharge temperature ADT ⇞ is displayed as active
line.
5. Press «Enter» to switch into setting mode.
The check box in the active line flashes.
8 9 p s i 0 8 : 1 5 1 6 3 ° F
Fallen airend discharge temperature
9.1 TÜV inspection
Menu
·········
Airend discharge temperature ADT ⇞ : ☐
Active line
Offset : 0 °C ¦ ADT ⇞ 0.0 °C
Reset: ☐
6. Use the «UP» key to activate the check box.
12 Checking the temperature sensor and overheating shutdown
function
20
Quick user guide Controller
SIGMA CONTROL 2 SCREW FLUID 1.1.3
9_9450 03 USE
Summary of Contents for ESD 352 SFC
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 171: ...KKW SSC 2 03 en 01 BA SIGMA CONTROL FLUID KKW SSC 2 03 01 20130805 113302...
Page 173: ......
Page 175: ...Contents ii Quick user guide Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03 USE...
Page 215: ...Contents iv Service manual Controller SIGMA CONTROL 2 SCREW FLUID 1 1 3 9_9450 03USE...
Page 392: ...KKW GBASE 1 00 en ERSATZTEILE 10357405_10 ESD 2C 20130903 115349...