PIC port information:
Fiber Xcvr vendor
Port Cable type type Xcvr vendor part number Wavelength
0 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm
1 10GBASE LR SM FINISAR CORP. FTLX1471D3BNL-J1 1310 nm
3 10GBASE LR SM FINISAR CORP. FTLX1471D3BNL-J1 1310 nm
6 10GBASE SR MM OPNEXT, INC. TRS2001EM-0014 850 nm
7 10GBASE SR MM OPNEXT, INC. TRS2001EM-0014 850 nm
10 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm
11 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850 nm
12 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm
14 10GBASE SR MM SumitomoElectric SPP5200SR-J6-M 850 nm
15 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850 nm
16 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850 nm
19 10GBASE LR SM OPNEXT,INC TRS5020EN-S201 1310 nm
21 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850 nm
22 10GBASE LR SM FINISAR CORP. FTLX1471D3BNL-J1 1310 nm
23 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850 nm
user@host>show chassis pic fpc-slot 3 pic-slot 0
FPC slot 3, PIC slot 0 information:
Type 4x100GE CFP2
State Online
PIC version 1.1
Uptime 13 minutes, 35 seconds
PIC port information:
Fiber Xcvr vendor Wave- Xcvr
Port Cable type type Xcvr vendor part number length Firmware
0 100GBASE LR4 SM Oclaro Inc. TRB5E20ENF-LF150 1309 nm 0.0
1 100GBASE LR4 SM Oclaro Inc. TRB5E20ENF-LF150 1309 nm 0.0
2 100GBASE LR4 SM Oclaro Inc. TRB5E20ENF-LF150 1309 nm 0.0
3 100GBASE LR4 SM Oclaro Inc. TRB5E20ENF-LF150 1309 nm 0.0
To troubleshoot the PIC cables:
1. Check if the optical cables are plugged into the optics properly and ensure that they are intact.
627
Summary of Contents for PTX5000
Page 1: ...PTX5000 Packet Transport Router Hardware Guide Published 2022 12 04...
Page 59: ...NOTE The PDUs contain no fans but are cooled by the fans in the power supply modules 41...
Page 63: ...NOTE The PDUs contain no fans but are cooled by the fans in the power supply modules 45...
Page 77: ...High Capacity Delta AC PDU LEDs 66 High Capacity Wye AC PDU 68 59...
Page 78: ...Three Phase Delta AC PDU LEDs Figure 29 on page 61 shows the three phase delta AC PDU LEDs 60...
Page 81: ...Three Phase Wye AC PDU LEDs Figure 30 on page 64 shows the three phase wye AC PDU LEDs 63...
Page 228: ...2 Remove each bracket Figure 81 Removing the Center Mounting Bracket 210...
Page 234: ...8 Move the lift away from the rack 216...
Page 235: ...Figure 83 Loading the PTX5000 onto the Lift 217...
Page 270: ...Figure 119 Connecting 20 A Inputs to a High Capacity Single Phase AC PDU 252...
Page 304: ...Figure 140 Installing the Front Door on a PTX5000 in a Four Post Rack 1 Side panels 2 Door 286...
Page 349: ...6 Discard the air filter Figure 154 Removing a Horizontal Air Filter Tray 331...
Page 352: ...Figure 157 Installing the Horizontal Air Filter 334...
Page 354: ...6 Discard the air filter Figure 158 Removing a Vertical Air Filter Tray 336...
Page 357: ...Figure 161 Installing a Vertical Air Filter Tray 339...
Page 428: ...Figure 216 Connecting 20 A Inputs to High Capacity Single Phase AC PDU 410...
Page 429: ...Figure 217 Connecting 30 A inputs to High Capacity Single Phase AC PDU 411...
Page 447: ...8 Insert the input power tray into the PDU Figure 228 Installing a 60 A Input Power Tray 429...
Page 448: ...Figure 229 60 A DC Input Power Terminals 430...
Page 531: ...Figure 276 Do Not Carry an FPC with Only One Hand 513...
Page 584: ...5 CHAPTER Troubleshooting Hardware Troubleshooting PTX5000 Components 567...
Page 651: ...6 CHAPTER Returning the Chassis or Components Returning the PTX5000 Chassis or Components 634...
Page 662: ...Figure 303 FPC2 PTX P1A Serial Number Label 644...
Page 663: ...Figure 304 FPC3 PTX U2 and FPC3 PTX U3 Serial Number Label 645...
Page 669: ...Figure 309 DC PDU Serial Number Label 651...
Page 670: ...Figure 310 AC PDU Serial Number Label 652...