Problem
Description
The following alarms or other conditions indicate a problem with the temperature of the hardware
components:
•
lists the alarms.
• The PTX5000 is powered off immediately if the temperature of a component exceeds the
preconfigured maximum
Fire Shutdown
threshold.
Solution
To troubleshoot temperature alarms:
1. Find the source of the problem by looking at the display on the craft interface. The number of alarm
conditions, as well as the source of each alarm, appears on the screen. Issue the
show chassis alarms
command to get information about the source of an alarm condition:
user@host> show chassis alarms
2. Verify that there is sufficient air flow. See
"PTX5000 Clearance Requirements for Airflow and
Hardware Maintenance" on page 168
,
"Maintaining the PTX5000 Fan Trays" on page 320
, and
"Maintaining the PTX5000 Air Filters" on page 329
Place your hand near the exhaust vents at the rear of the chassis to determine whether the fans are
pushing air out of the chassis.
• Zone 0: The air exhausts from the left side of the SIBs.
• Zone 1: The exhaust vent is located at the upper rear of the chassis.
• Power system: The air exhausts from the power supply modules (PSMs).
3. Verify that the cooling system in the chassis is operating properly. See
PTX5000 Cooling System" on page 574
4. Verify that the room temperature is within acceptable limits. Use the
show chassis temperature-thresholds
to show the temperature thresholds for various components.
579
Summary of Contents for PTX5000
Page 1: ...PTX5000 Packet Transport Router Hardware Guide Published 2022 12 04...
Page 59: ...NOTE The PDUs contain no fans but are cooled by the fans in the power supply modules 41...
Page 63: ...NOTE The PDUs contain no fans but are cooled by the fans in the power supply modules 45...
Page 77: ...High Capacity Delta AC PDU LEDs 66 High Capacity Wye AC PDU 68 59...
Page 78: ...Three Phase Delta AC PDU LEDs Figure 29 on page 61 shows the three phase delta AC PDU LEDs 60...
Page 81: ...Three Phase Wye AC PDU LEDs Figure 30 on page 64 shows the three phase wye AC PDU LEDs 63...
Page 228: ...2 Remove each bracket Figure 81 Removing the Center Mounting Bracket 210...
Page 234: ...8 Move the lift away from the rack 216...
Page 235: ...Figure 83 Loading the PTX5000 onto the Lift 217...
Page 270: ...Figure 119 Connecting 20 A Inputs to a High Capacity Single Phase AC PDU 252...
Page 304: ...Figure 140 Installing the Front Door on a PTX5000 in a Four Post Rack 1 Side panels 2 Door 286...
Page 349: ...6 Discard the air filter Figure 154 Removing a Horizontal Air Filter Tray 331...
Page 352: ...Figure 157 Installing the Horizontal Air Filter 334...
Page 354: ...6 Discard the air filter Figure 158 Removing a Vertical Air Filter Tray 336...
Page 357: ...Figure 161 Installing a Vertical Air Filter Tray 339...
Page 428: ...Figure 216 Connecting 20 A Inputs to High Capacity Single Phase AC PDU 410...
Page 429: ...Figure 217 Connecting 30 A inputs to High Capacity Single Phase AC PDU 411...
Page 447: ...8 Insert the input power tray into the PDU Figure 228 Installing a 60 A Input Power Tray 429...
Page 448: ...Figure 229 60 A DC Input Power Terminals 430...
Page 531: ...Figure 276 Do Not Carry an FPC with Only One Hand 513...
Page 584: ...5 CHAPTER Troubleshooting Hardware Troubleshooting PTX5000 Components 567...
Page 651: ...6 CHAPTER Returning the Chassis or Components Returning the PTX5000 Chassis or Components 634...
Page 662: ...Figure 303 FPC2 PTX P1A Serial Number Label 644...
Page 663: ...Figure 304 FPC3 PTX U2 and FPC3 PTX U3 Serial Number Label 645...
Page 669: ...Figure 309 DC PDU Serial Number Label 651...
Page 670: ...Figure 310 AC PDU Serial Number Label 652...