3. Check the status of the PICs. issue the
show chassis fpc pic-status
command. The PIC slots in each FPC
are numbered from 0 through 1, top to bottom:
user@host> show chassis fpc pic-status
Slot 0 Online FPC E
PIC 0 Online 24x 10GE(LAN) SFP+
PIC 1 Online 24x 10GE(LAN) SFP+
Slot 2 Online FPC E
PIC 0 Online 24x 10GE(LWO) SFP+
PIC 1 Online 4x100GE CFP2
Slot 3 Online FPC E
PIC 0 Online 4x100GE CFP2
PIC 1 Online 4x100GE CFP2
Slot 4 Online FPC
PIC 0 Online 2x 100GE CFP
PIC 1 Online 2x 100GE CFP
Slot 7 Online FPC E
PIC 0 Online 48x10G/12x40G(LWO)QSFP+
PIC 1 Offline 4x100GE OTN CFP2
4. Issue the
show chassis pic fpc-slot
fpc-slot pic-slot pic-slot
command for more information about a
specific PIC.
user@host>show chassis pic fpc-slot 3 pic-slot 0
FPC slot 3, PIC slot 0 information:
Type 4x100GE CFP2
State Online
PIC version 1.1
Uptime 13 minutes, 35 seconds
user@host>show chassis pic fpc-slot 2 pic-slot 1
FPC slot 2, PIC slot 0 information:
Type 24x 10GE(LAN) SFP+
State Online
PIC version 1.14
Uptime 3 hours, 6 minutes, 30 seconds
626
Summary of Contents for PTX5000
Page 1: ...PTX5000 Packet Transport Router Hardware Guide Published 2022 12 04...
Page 59: ...NOTE The PDUs contain no fans but are cooled by the fans in the power supply modules 41...
Page 63: ...NOTE The PDUs contain no fans but are cooled by the fans in the power supply modules 45...
Page 77: ...High Capacity Delta AC PDU LEDs 66 High Capacity Wye AC PDU 68 59...
Page 78: ...Three Phase Delta AC PDU LEDs Figure 29 on page 61 shows the three phase delta AC PDU LEDs 60...
Page 81: ...Three Phase Wye AC PDU LEDs Figure 30 on page 64 shows the three phase wye AC PDU LEDs 63...
Page 228: ...2 Remove each bracket Figure 81 Removing the Center Mounting Bracket 210...
Page 234: ...8 Move the lift away from the rack 216...
Page 235: ...Figure 83 Loading the PTX5000 onto the Lift 217...
Page 270: ...Figure 119 Connecting 20 A Inputs to a High Capacity Single Phase AC PDU 252...
Page 304: ...Figure 140 Installing the Front Door on a PTX5000 in a Four Post Rack 1 Side panels 2 Door 286...
Page 349: ...6 Discard the air filter Figure 154 Removing a Horizontal Air Filter Tray 331...
Page 352: ...Figure 157 Installing the Horizontal Air Filter 334...
Page 354: ...6 Discard the air filter Figure 158 Removing a Vertical Air Filter Tray 336...
Page 357: ...Figure 161 Installing a Vertical Air Filter Tray 339...
Page 428: ...Figure 216 Connecting 20 A Inputs to High Capacity Single Phase AC PDU 410...
Page 429: ...Figure 217 Connecting 30 A inputs to High Capacity Single Phase AC PDU 411...
Page 447: ...8 Insert the input power tray into the PDU Figure 228 Installing a 60 A Input Power Tray 429...
Page 448: ...Figure 229 60 A DC Input Power Terminals 430...
Page 531: ...Figure 276 Do Not Carry an FPC with Only One Hand 513...
Page 584: ...5 CHAPTER Troubleshooting Hardware Troubleshooting PTX5000 Components 567...
Page 651: ...6 CHAPTER Returning the Chassis or Components Returning the PTX5000 Chassis or Components 634...
Page 662: ...Figure 303 FPC2 PTX P1A Serial Number Label 644...
Page 663: ...Figure 304 FPC3 PTX U2 and FPC3 PTX U3 Serial Number Label 645...
Page 669: ...Figure 309 DC PDU Serial Number Label 651...
Page 670: ...Figure 310 AC PDU Serial Number Label 652...