![JUKI LZ-2290A/IP-110A/SC-915 Instruction Manual Download Page 84](http://html.mh-extra.com/html/juki/lz-2290a-ip-110a-sc-915/lz-2290a-ip-110a-sc-915_instruction-manual_2029975084.webp)
81
*
Ref.
Page
*
*
*
Settng
level
Panel dsplay
Standard set value
Descrpton
Item
No.
1
2
1
1
2
2
2
2
2
2
2
2
2
2
1
1
5
7
8
10
11
12
13
18
19
21
22
23
24
28
0 to 9
0 to 8
0/1/2
150 to 3000
1/0
1/0
0 to 8
0/1/2
0/1/2
1/0
1/0
1/0
1/0
±15
0 to 30
N-SOFT
3
T-ACC
0
RATIO
0
S-BT
1350
NPS
0
SOUND
1
SW2
0
ASCNT
0
BNC
0
THOLD
0
N-NPL
0
F-CMSP
0
F-AFL
0
F-FAS
0
F-UTHR
1
Settng range
85
85
85
85
86
86
86
(2) Function setting list
Soft start
functon
Flcker
reducng
functon
Unt of
bobbn thread
countng down
Number of
rotaton of
reverse feed
sttchng
Settng of
needle bar stop
poston when
the sewng
machne stops.
Clck sound
of panel
swtch
Optonal
swtch
functon
selecton
Functon of
prohbtng
start of the
sewng
machne by
bobbn thread
counter
Brd's nest
preventon
functon
Needle
thread
release at
sewng start
functon
Functon
of neutral
presser lftng
Functon of
changeover of
compensatng
swtch on the
operaton panel
functon
Presser lftng
functon
selecton
Functon of
fine adjustment
of number of
rotaton
Number of
sttches of brd's
nest needle
thread release
The number of sttches to be sewn at a low speed when the soft-
start functon s used at the start of sewng.
0 : Soft-start functon s not operatve
Flicker reducing function (If the hand lamp flickers.)
0 : Flcker reducng functon s not operatve
1 : Less effective ıî 8 : Highly effective
Unt of bobbn thread countng down
0 : Count/10 sttches
1 : Count/15 sttches
2 : Count/20 sttches
Sewng speed of reverse feed sttchng
Position of needle bar is specified when the sewing machine stops.
0 : Predetermned lowest poston
1 : Predetermned hghest poston
Click sound of panel switch is specified.
0 : Wthout clck
1 : Wth clck
Swtchng of functons of optonal swtch
0 : No functon
1 : Needle up/down compensatng sttchng
2 : No functon
3 : No functon
4 : Thread trmmng functon
5 : Presser foot lftng functon
6 : One sttch compensatng sttchng
7 : No functon
8 : Pedal neutral presser lftng functon selecton
Do not set to 2, 3 and 7. If these numbers are set, trouble or
accdent wll be caused.
Functon of prohbtng start of the sewng machne by bobbn
thread counter (After thread trmmng)
0 : When countng s out (-1 or less), functon of prohbtng
start of the sewng s not operatve.
1 : When countng s out (-1 or less), functon of prohbtng
start of the sewng machne s operatve.
2 : Functon of “1” + counter (-1 or less) stop (temporary stop)
Effectve n combnaton wth machne head wth brd's nest
preventon functon
0 : Wthout brd's nest preventon functon
1 : Wth brd's nest preventon functon
2 :
Wth brd’s nest preventon functon wth needle thread release after clamp functon
Effectve n combnaton wth machne head wth brd's nest
preventon functon
0 : Wthout needle thread release functon
1 : Wth needle thread release functon
Functon of lftng presser foot when the pedal s n neutral poston.
0 : Functon of neutral automatc presser lftng s not operatve.
1 : Selecton of functon of neutral presser lftng.
Functon of needle up/down compensatng swtch on the
operaton panel can be changed.
0 : Needle up/down compensaton
1 : One sttch compensaton
Presser lftng functon selecton
0 : Ineffectve
1 : Effectve
Number of rotaton can be compensated.
Be sure to normally use ths functon wth "0".
Effectve n combnaton wth machne head wth brd's nest
preventon functon
Number of sttches from start of sewng to release of needle
thread can be set.
*
Do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the time of
delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated.
If it is necessary to change the set value, please purchase the Engineer's Manual and follow the instructions. (Descriptions of setting
in this list are the standard values at the time of delivery of LZ-2290A.)
However, contents of function setting are subject to change for improvement of function and performance without notice.