Datacom Testing
BER Testing
SmartClass E1 Tester User’s Guide
63
3
Connect the other end(s) of the adaptor cable to the test access point.
You have finished connecting the cables.
BER Testing
Performing a bit error rate test (BERT) involves configuring the test settings,
including logic error insertion; connecting the E1/Datacom Tester to the a
circuit; starting the test and inserting logic errors; and observing the results.
To do a bit error rate test
1
Set the test mode to DTE or DCE Emulation. See
.
2
Select a pattern. See
“Specifying a BERT pattern” on page 55
3
Specify the other settings on the Configuration menu, as needed.
See
“Specifying the interface standard” on page 53
“Specifying timing parameters” on page 54
“Specifying polarity settings” on page 55
.
“Specifying data parameters” on page 57
.
“Specifying async settings” on page 58
“Specifying flow control settings” on page 59
“Specifying G.821 performance settings” on page 60
4
Specify how errors will be inserted. See
“Specifying error settings” on
5
If you want to run the test for a specific amount of time, configure the timed
test settings. See
6
If this is your first test of the day, perform a self test on the E1/Datacom
Tester. See
“Performing a self test” on page 61
7
Connect the E1/Datacom Tester to the circuit. See
Datacom Tester to the circuit” on page 61
.
8
From the Action menu, select
Restart
.
9
Verify that the
Sync
LED illuminates green.
10
To insert errors, press the
* Action
key to view the Error menu, and then
select press
1
.
This will do one of the following:
–
Enable
or
Disable Bit Error Rate Insertion
— begin inserting bit
errors at the rate specified on the Error Settings menu (appears only if
the Rate Type is set to “Rate”).
–
Bit Error Multi Insert
— inserts multiple bit errors with each press
(appears only if the Rate Type is set to “Multiple”).
–
Bit Error Insert
— inserts one bit error with each press (appears only if
the Rate Type is set to “Single”).
11
From the BERT menu, select
Results
and then the BERT category.
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Page 143: ......