Chapter 5
Datacom Testing
Performing a self test
SmartClass E1 Tester User’s Guide
61
Performing a self test
Before you begin testing, you should perform a self test on the E1/Datacom
Tester to make sure it is operating properly on the selected interface standard.
You can test the E1/Datacom Tester and the test cable.
To perform a self test on the E1/Datacom Tester
1
Configure a test.
2
On the test menu, select
Action
.
3
Select
Self Loop
, and then select one of the following options:
–
Enable Internal Loop
— This option connects the transmitter to the
receiver without involving amplifiers or cables. Skip to
.
–
Enable Cable Test
— This option tests the amplifiers along with one of
the emulation cables. When you select this option, the E1/Datacom
Tester automatically sets the Rx Input setting to unterminated and the
Tx Timing setting to Tx SYNTH. The maximum data rate supported for
this option is 1 MHz.
Proceed to
4
If you selected Enable Cable Test, connect the cable's DCE connector to
the DTE connector.
5
After you have connected the emulation cables (if applicable), select
Restart
from the Action menu.
6
On the test menu, select
Results
.
If an “All Results OK” message appears, the unit and interface are oper-
ating properly.
If errors appear in the Summary result category, there is a problem with
the E1/Datacom Tester or the cables.
You have completed the self test.
Connecting the E1/Datacom Tester to the circuit
To connect the E1/Datacom Tester to the circuit, you must have the correct
adaptor cable for the test operation and the interface standard you want to test.
For a list of available cables, see
. For information on
ordering cables, contact your local JDSU sales office.
The following sections describe how to connect the E1/Datacom Tester for
monitor or DTE/DCE emulation tests.
NOTE:
All DTE and DCE emulation cables have yellow bands. All monitor cables
have blue bands.
When you connect a cable to the E1/Datacom Tester and the Signal result
screen is currently visible, the unit will display the cable type in the lower
right corner of the screen.
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...