Chapter 7
Test Results
Jitter results
SmartClass E1 Tester User’s Guide
89
Jitter results
lists and describes each of the test results in the Jitter category.
Graphical and Tabular jitter
results
When testing jitter, you can view results in a graphical or tabular format by
selecting the corresponding result categories in the Interface group.
Jitter Graph
The jitter graph is available when manually testing jitter, and when measuring
MTJ and Fast MTJ.
MTJ Graph and Table
The MTJ graph and table are available when measuring MTJ and Fast MTJ.
JTF Graph
The JTF graph is available when measuring JTF.
Signal results
The Signal results report the same results as the other E1 tests. See
.
Interface results
The Interface results report the same results as the other E1 tests. See
BERT results
The BERT results report the same results as the other E1 tests. See
.
Event Log
The Event Log results report the same results as the other E1 tests. See
.
Event Histogram
The Event Histogram results report the same results as the other E1 tests. See
Table 22
Jitter test results
Test Result
Description
Rx Jitter (UIpp)
The maximum peak-to-peak jitter measured since
starting or restarting the test, expressed in UIpp.
Max Rx Jitter (UIpp)
The maximum peak-to-peak jitter measured since
starting or restarting the test, expressed in UIpp.
Rx 18-100 KHz (UIpp)
The peak-to-peak jitter outputted from the
18-100 k filter since starting or restarting the test,
expressed in UIpp.
Max Rx 18-100 KHz (UIpp)
The maximum peak-to-peak jitter outputted from
the 18-100 k filter since starting or restarting the
test, expressed in UIpp.
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Page 143: ......