Chapter 5
Datacom Testing
Frame Relay testing
SmartClass E1 Tester User’s Guide
69
3
If you need to specify other settings for the test, press
Cancel
to return to
the Configuration menu.
The frame header settings are configured.
Configuring the LMI Settings
Local Management Interface (LMI) is a signaling mechanism often used on
frame relay networks to communicate information about the status of a network
connection. With the Frame Relay testing option, the E1/Datacom Tester can
monitor and emulate LMI signals on UNI-user, UNI-network, and NNI inter-
faces for the following LMI types:
– Annex D (ANSI T1.617)
– Annex A (ITU-T Q.933)
– LMI Rev 1
The E1/Datacom Tester can capture LMI messages, decode them, and then
display them in the Trace result category. Other LMI link results include the LMI
type, message count, errors, and timeouts. For more information about LMI
results, see
To specify LMI settings
1
If you haven’t already done so, launch the Frame Relay application (see
“Launching the Frame Relay application” on page 64
2
On the Configuration menu, select
FR LMI Settings
, and then specify the
following settings:
Lng Frm Rx
Thresh
Enter a value, from
5
to
9999
bytes, to indicate the long
frame receive threshold.
The
E1/Datacom Tester
will maintain a count of
received frames that exceed the specified threshold.
Setting
Parameters
Setting
Parameters
Type
Select the type of local management interface (LMI):
–
Off
–
T1.617 Annex D
–
Q.933 Annex A
–
LMI Rev 1
–
Auto
Status Poll Time
Enter a value, from
5
to
30
, to indicate the status poll
time in seconds.
Full Poll Time
Enter a value (
n
), from
1
to
255
, to indicate that the
E1/
Datacom Tester
should perform a full status poll time
every
nth
poll cycle. For example, if you enter 4, the
E1/Datacom Tester
will perform a full status poll
every 4th time.
Interface
Select one of the following interfaces:
–
UNI-U
(user)
–
UNI-N
(network)
– NNI
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Page 143: ......