Chapter 1
Getting Started
Exploring the front panel
SmartClass E1 Tester User’s Guide
7
Status LEDs
These indicators report the status of the unit. The function of the LEDs change
depending on the application.
describes each of the Status LEDs.
Table 6
Status LEDs
Status LED
Description
Sync
For E1 testing:
Green
– Solid—A signal is present and synchronization is established
on all active receivers.
– Flashing—Auto-framing is running on at least one active
receiver.
Red
– At least one of the active receivers does not have frame syn-
chronization.
Off
– No signal has been detected on any receiver.
For Datacom testing:
Green
– Solid—A receive clock is present.
Red
– Solid—A receive clock was present at some point in the past,
but was lost.
Off
– No receive clock has been detected on any receiver.
Data/LpBK
Green
– Solid—Synchronization is established with BERT pattern for all
active receivers.
– Flashing—Auto-pattern is running on at least one active
receiver.
Red
– At least one of the active receivers does not have pattern syn-
chronization.
Amber
–
For E1 testing:
The E1 Tester has been placed in a line loop-
back mode.
Off
– The E1 Tester is not in a line loopback mode, which means the
selected traffic pattern is live on all active receivers, or no pat-
tern synchronization has been detected on the receiver.
Err/Alm
Red
– Flashing—The LED flashes for one second when an error or
alarm occurs. Or, for E1 testing, flashes when the unit is
searching for framing or a pattern during Auto Config.
Amber
– At least one error or alarm has occurred since that last reset.
Off
– All Summary results are OK. No error or alarm has been
received.
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Page 143: ......