Chapter 4
E1 Testing
Measuring timing slips
SmartClass E1 Tester User’s Guide
39
11
Restart the test.
12
To view other results, see
.
You have finished monitoring the circuit.
Measuring timing slips
The SmartClass E1 allows you to monitor the timing between two E1 signals
for timing slips. For example, you can check customer premises equipment
against a master clock at the central office, or you can compare two lines of
network equipment. The SmartClass measures the difference, in bits per
second (bit/s), between the opposite receiver (Rx) or the external 2M Refer-
ence clock.
The following procedure describes how to measure timing slips.
To measure timing slips
1
Launch the E1
BERT
“Launching an E1 test application”
2
On the Configuration menu, select
Test Mode
.
A list of test modes appears.
3
Select
Monitor
.
4
Connect the E1 Tester to a reference signal and to the test signal:
– Connect the 2M Reference Clock cable from the E1 Tester’s RX2/
Ext Clk jack to an E1 BITS clock or a known good reference signal.
– Connect a cable from the E1 Tester RX1/TX1 jack to the signal to be
tested.
5
On the Configuration menu, select
Interface Settings
.
6
Select
Slip Reference
and then select the clock reference for timing slips.
7
Restart the test.
This will clear all alarms and begin a new test.
8
On the test menu, select
Results
, and then select
Signal Results
.
The Signal Results window appears.
9
Check the timing slips result.
For a description of the result, see
.
You have finished measuring timing slips.
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Page 143: ......