USER’S MANUAL
59
MENU SETUP
6.3.5 REPEAT RECORD
•
You could overwrite the recorded data automatically.
•
This is a “first in first out” system, it will delete a period of oldest data to do the cycle record.
•
Overwritten data will no longer recovery.
•
This setup effect with “record HDD” as well as “backup HDD”.
①
Enter the
RECORD > REPEAT RECORD
menu.
②
C
hoose from “ON” or “OFF”. The default is “ON”.
③
It is possible to set a point of time to activate the REPEAT RECORD ALARM. The value is from
5% to 10%. And default is “5%”.
6.3.6 PLAY MODE
①
Enter the
RECORD > PLAY MODE
menu.
Note:
- REPEAT RECORD ALARM is the rest capacity of the HDD.
- If you set “REPEAT RECORD ALARM” to 5%, alarm will activate when the rest of total HDD capacity is 5%.
Note:
- FRAME : It will playback images in frame mode which is useful for recorded images in high frame rate. This
may occur moving artifact with recorded images in low frame rate.
- FIELD : It will playback images in field mode. This reduces the resolution, but is suitable for recorded images
in low frame rate.
NOTE :
- AUDIO SELECT + CHANNEL during live or playback
- 16CH, 8CH DVR has 4CH Audio inputs.
TIPS