425
100
Figure 59: Disassembly of the upper half casing
* 164A for 4x6-10 and 4x6-11 pumps. 165B for all other pump sizes.
1.
Loosen and remove the casing nuts (425) and taper pins.
2.
Use the jacking bolts (provided with the pump) to loosen the upper half from the lower half of the
casing (100).
WARNING:
Risk of severe physical injury or death from explosion of trapped liquid. Never use heat to re-
move parts unless explicitly stated in this manual.
3.
Insert eyebolts (not supplied) in the pre-drilled threaded holes in the perimeter of the upper half of
the casing. Remove the upper half to the work area.
WARNING:
Use the eyebolts to lift only the upper half of the casing. They will not support the weight of the
entire pump.
6.4 Disassembly
Model 3600 i-FRAME API610 11th Edition / ISO 13709 2nd Edition to current API BB3 Multi-Stage, Axially Split Installa-
tion, Operation, and Maintenance Manual
85