P
A
Y
X
Figure 12: Dial indicator attachment
2.
Rotate the pump coupling half (X) in order to check that the indicators are in contact with the driver
coupling half (Y) but do not bottom out.
3.
Adjust the indicators if necessary.
4.4.5 Perform angular alignment for a vertical correction
1.
Set the angular alignment indicator to zero at the top-center position (12 o’clock) of the driver cou-
pling half (Y).
2.
Rotate the indicator to the bottom-center position (6 o’clock).
3.
Record the indicator reading.
When the
reading val-
ue is...
Then...
Negative
The coupling halves are farther apart at the bottom than at the top. Perform one of
these steps:
•
Add shims in order to raise the feet of the driver at the shaft end.
•
Remove shims in order to lower the feet of the driver at the other end.
Positive
The coupling halves are closer at the bottom than at the top. Perform one of these
steps:
•
Remove shims in order to lower the feet of the driver at the shaft end.
•
Add shims in order to raise the feet of the driver at the other end.
Y X
1
Item Description
1.
Shims
Figure 13: Example of incorrect vertical alignment (side view)
4.
Repeat the previous steps until the permitted reading value is achieved.
4.4.6 Perform angular alignment for a horizontal correction
4.4 Pump-to-driver alignment
28
Model 3600 i-FRAME API610 11th Edition / ISO 13709 2nd Edition to current API BB3 Multi-Stage, Axially Split Installa-
tion, Operation, and Maintenance Manual
Summary of Contents for GOULDS PUMPS 3600 i-FRAME
Page 2: ......