8.
Repeat Steps 3. through 5. for the rear end of the coupling guard half, except that you hand tighten
the bolt.
9.
Slide the rear coupling guard half towards the motor so that it completely covers the shafts and cou-
pling.
1
2
Item Description
1.
Driver
2.
Slide to fit
Figure 26: Slide to fit
10. Repeat Steps 3. through 5. for the center slots in the coupling guard.
11. Firmly tighten all bolts (569E) on the guard assembly.
5.5 Bearing lubrication
Precautions
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. Ensure
bearings are properly lubricated prior to startup.
Pumps are shipped without oil
You must lubricate oil-lubricated bearings at the job site.
Ring oil lubrication
Ring oil-lubricated bearings are standard. Bearing housings are supplied with constant-level oilers and
sight glasses. Make sure that oil ring properly seated in the grooves in the shaft.
Pure or purge oil-mist lubrication
Pure or purge oil mist are optional features. Follow the oil-mist generator manufacturer's instructions.
The inlet and outlet connections are located on the top and bottom of the bearing housing, respectively.
5.5 Bearing lubrication
Model 3600 i-FRAME API610 11th Edition / ISO 13709 2nd Edition to current API BB3 Multi-Stage, Axially Split Installa-
tion, Operation, and Maintenance Manual
47