Goodrive300-21 integrated machine for air compressor
Function description
-
44
-
Function
code
Name
Description
Default Modify
P13.12
High frequency
compensation
coefficient
Valid when the motor speed exceeds the rated
speed. If oscillation occurred to the motor,
adjust this parameter properly.
Setting range: 0.0
–100.0%
50.0%
○
P14.00
Local
communication
address
1
–247; 0 indicates a broadcast address
2
○
P14.01
Communication
baud rate
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
4
○
P14.02
Data bit check
0: No check (N, 8, 1) for RTU
1: Even check (E, 8, 1) for RTU
2: Odd check (O, 8, 1) for RTU
3: No check (N, 8, 2) for RTU
4: Even check (E, 8, 2) for RTU
5: Odd check (O, 8, 2) for RTU
1
○
P14.03
Communication
response delay
0
–200ms
5
○
P14.04
Communication
timeout time
0.0 (invalid), 0.1
–60.0s
0.0s
○
P14.05
Transmission error
processing
0: Report an alarm and coast to stop
1: Keep running without reporting an alarm
2: Stop in enabled stop mode without
reporting an alarm (applicable only to
communication mode)
3: Stop in enabled stop mode without
reporting an alarm (applicable to any mode)
0
○
P14.06
Communication
processing action
0x00
–0x11
LED ones: Writing operation
0: Respond to write operations
1: Not respond to write operations
LED tens: Communication encryption
0: Disabled
1: Enabled
0x00
○