Goodrive300-21 integrated machine for air compressor
Function description
-
43
-
Function
code
Name
Description
Default Modify
1: Do not act upon an undervoltage fault
LED tens place:
0: Act during automatic reset
1: Do not act during the automatic reset period
P11.14
Speed deviation
detection value
0.0
–50.0%
10.0%
○
P11.15
Speed deviation
detection time
0.0
–10.0s (No speed deviation protection for
the value=0.0)
0.5s
○
P11.16
Automatic
frequency-reduction
during voltage drop
0: Disable
1: Enable
1
○
P13.00
Reduction
coefficient of pull-in
current
0.0
–100.0%
50.0%
○
P13.01
Detection mode of
initial pole
0: No detection
1: High frequency superimposition (reserved)
2: Pulse superimposition (reserved)
0
◎
P13.02
Pull-in current 1
0.0%
–100.0% (of the motor rated current)
20.0%
○
P13.03
Pull-in current 2
0.0%
–100.0% (of the motor rated current)
10.0%
○
P13.04
Source-current
switchover
frequency
0.00Hz
–P00.03 (Max. output frequency)
30.00Hz
○
P13.05
High frequency
overlay frequency
(reserved)
200Hz
–1000Hz
500Hz
◎
P13.06
High frequency
superimposed
voltage
0.0
–300.0% (of the motor rated voltage)
40.0%
◎
P13.08
Control parameter 1 0
–FFFF
0x120
○
P13.09
Control parameter 2 0
–300.00
5.00
○
P13.11
Maladjustment
detection time
Used to adjust the responsiveness of
anti-maladjustment function. If the load inertia
is large, increase the value of this parameter
properly, however, the responsiveness may
slow down accordingly.
Setting range: 0.0
–10.0s
0.5s
○