Goodrive300-21 integrated machine for air compressor
Function description
-
46
-
Function
code
Name
Description
Default Modify
P15.06
Delay time of
auxiliary pressure
detection
0
–65535s
Note:
The value 0 indicates that the low
auxiliary pressure fault will not be detected.
0
○
P15.07
Auxiliary pressure
low protection point
0.00
–20.00MPa
When the auxiliary pressure protection is
enabled (P18.39=1) and the auxiliary pressure
is less than the P15.11 set value, an auxiliary
pressure low fault is reported.
Note:
Auxiliary pressure low fault detection is
disabled when the air compressor is asleep.
0.00
○
P15.08
Dynamic password
0
–9999
Note:
This value is automatically refreshed
every time the device is powered on/every 8
hours/every time a new P15.09 value is
entered.
●
P15.09
Handshake
password
0
–9999
Note:
This is used to turn on or turn off the
handshake protocol.
0
◎
P15.10
Handshake timeout
time
0
–65535s
Note:
If the handshake fails after the time set
in P15.10, a HAnd fault is reported, and no
fault is reported when it is set to 0.
20s
○
P15.11
Handshake status
0
–1
0: Disabled
1: Enabled
0
●
P15.12
Number of decimal
points of pressure
0
–1
0: 2 bits
1: 3 bits
0
○
P17.00
Set frequency
0.00Hz
–P00.03
0.00Hz
●
P17.01
Output frequency 0.00Hz
–P00.03
0.00Hz
●
P17.02
Ramp reference
frequency
0.00Hz
–P00.03
0.00Hz
●
P17.03
Output voltage
0
–1200V
0V
●
P17.04
Output current
0.0
–3000.0A
0.0A
●
P17.05
Motor rotation
speed
0
–65535RPM
0 RPM
●
P17.06
Torque current
-3000.0
–3000.0A