Goodrive300-21 integrated machine for air compressor
Function description
-
35
-
Function
code
Name
Description
Default Modify
P07.00
User password
0
–65535
0
○
P07.01
Parameter copy
0: No operation
1: Upload parameters from the local address
to the keypad
2: Download parameters (including motor
parameters) from the keypad to the local
address
3: Download parameters (excluding groups
P02 and P12) from the keypad to the local
address
4: Download parameters (only including
groups P02 and P12) from the keypad to the
local address
Note:
After any operation among 1
–4 is
complete, the parameter restores to 0. The
upload and download functions are not
applicable to group P29.
Tens place: Parameter group setting
0
–4: Group 1–group 5
Setting range: 0x00
–0x44
0x00
◎
P07.11
Rectifier bridge
temperature
0
–100.0°C
●
P07.12 Inverter temperature 0
–100.0°C
●
P07.13
Control board
software version
1.00
–655.35
●
P07.14
Local accumulative
running time
0
–65535h
●
P07.15
Inverter electricity
consumption
high-order bits
0
–65535 kWh (*1000)
●
P07.16
Inverter electricity
consumption
low-order bits
0.0
–999.9 kWh
●
P07.17
Inverter model
0: G type
1: P type
●
P07.18
Inverter rated power 0.4
–3000.0kW
●