Goodrive300-21 integrated machine for air compressor
Communication protocol
-
105
-
Function
Address
Data description
R/W
Read high speed pulse 1
input
3010H
R
Read high speed pulse 2
input
3011H
R
Read the actual step of
multi-step speed
3012H
R
External length value
3013H
R
External counting value
3014H
R
Torque setting
3015H
R
Inverter identification
code
3016H
R
Fault code
5000H
R
C.2.6 Error messages
Table C-2 Code and definition for fault message response
Code
Name
Definition
01H
Invalid command
The command code received by the upper computer is not allowed to
be executed. The possible causes are as follows:
1.
The function code is applicable only on new devices and is not
implemented on this device.
2.
The slave is in faulty state when processing this request.
02H
Invalid data
address
For the inverter, the data address in the request of the upper
computer is not allowed. In particular, the combination of the register
address and the number of the to-be-sent bytes is invalid.
03H
Invalid data value
The received data domain contains a value that is not allowed. The
value indicates the error of the remaining structure in the combined
request.
Note:
It does not mean that the data item submitted for storage in the
register includes a value unexpected by the program.
04H
Operation failure
The parameter is set to an invalid value in the write operation. For
example, a function input terminal cannot be set repeatedly.
05H
Incorrect
password
The password entered in the password verification address is
different from that is specified by P07.00.
06H
Incorrect data
frame
The data frame sent from the upper computer is incorrect in the
length, or in the RTU format, the value of the CRC check bit is
inconsistent with the CRC value calculated by the lower computer.
07H
Parameter
read-only
The parameter to be modified in the write operation of the upper
computer is a read-only parameter.