Goodrive300-21 integrated machine for air compressor
Function description
-
58
-
Function
code
Name
Description
Default Modify
1: Fault; 0: normal
BIT4: External fault signal 1
1: Fault; 0: normal
BIT5: External fault signal 2
1: Fault; 0: normal
BIT6: Solenoid valve signal state
1: Load; 0: unload
BIT7: Auxiliary motor state
1: Run; 0: Stop
BIT8: Pressure pre-alarm signal
1: Pressure pre-alarm; 0: normal
BIT9: Temperature pre-alarm signal
1: Temperature pre-alarm; 0: normal
BIT10: Pressure alarm signal
1: Pressure alarm; 0: normal
BIT11: Temperature alarm signal
1: Temperature pre-alarm; 0: normal
BIT12: Pressure signal
1: Pressure signal fault: 0: normal
BIT13: Temperature signal
1: Temperature signal fault; 0: normal
BIT14: Low temperature protection
1: Low temperature alarm; 0: normal
BIT15: Master state
1: Run; 0: Stop
P19.14
Signal state 2
0
–0xFFFF
BIT0: Maintenance reminder of part 1
1: maintenance required; 0: normal
BIT1: Maintenance reminder of part 2
1: maintenance required; 0: normal
BIT2: Maintenance reminder of part 3
1: maintenance required; 0: normal
BIT3: Maintenance reminder of part 4
1: maintenance required; 0: normal
BIT4: Maintenance reminder of part 5
1: maintenance required; 0: normal
BIT5: Auxiliary pressure signal
1: auxiliary pressure signal fault; 0: normal
BIT6: Auxiliary temperature signal
1: auxiliary temperature signal fault; 0: normal
BIT7: Auxiliary pressure pre-alarm signal
0
●