Goodrive300-21 integrated machine for air compressor
Function description
-
42
-
Function
code
Name
Description
Default Modify
LED tens place:
0: Output phrase loss protection disabled
1: Output phrase loss protection enabled
LED hundreds place:
0: Hardware protection against input phrase
loss disabled
1: Hardware protection against input phrase
loss enabled
Note:
The hundreds place of the LED detects
input phase loss by hardware detection circuit.
LED thousands place:
0: Phase sequence protection disabled
1: Phase sequence protection enabled
P11.01
Frequency drop at
transient power-off
0: Disable
1: Enable
0
○
P11.02
Frequency drop rate
at transient
power-off
0.00Hz
–P00.03 (Max. output frequency)/s
10.00Hz/s
○
P11.03
Overvoltage stalling
protection
0: Disable
1: Enable
1
○
P11.04
Overvoltage stalling
protection voltage
120
–150% (standard bus voltage) (380V)
140%
○
P11.05
Current limit mode
0x00
–0x11
Ones place: Current limit action selection
0: Invalid
1: Always valid
Tens place: Hardware current limit overload
alarm
0: Valid
1: Invalid
01
◎
P11.06
Automatic current
limit threshold
50.0
–200.0%
160.0%
◎
P11.07
Frequency drop rate
during current limit
0.00
–50.00Hz/s
10.00Hz/s
◎
P11.13
Fault output terminal
action upon fault
occurring
0x00
–0x11
LED ones place:
0: Act upon an undervoltage fault
0x00
○