Goodrive300-21 integrated machine for air compressor
Function description
-
32
-
Function
code
Name
Description
Default Modify
P05.18
S3 switch-on delay 0.000
–50.000s
0.000s
○
P05.19
S3 switch-off delay 0.000
–50.000s
0.000s
○
P05.20
S4 switch-on delay 0.000
–50.000s
0.000s
○
P05.21
S4 switch-off delay 0.000
–50.000s
0.000s
○
P05.22
S5 switch-on delay 0.000
–50.000s
0.000s
○
P05.23
S5 switch-off delay 0.000
–50.000s
0.000s
○
P05.32
P1 lower limit
P05.34
P05.32
P05.33
P05.35
17.19
Mapping
percentage
Mapping
settings
(%)
Input
voltage
0
P05.32 setting range: 0.00V
–P05.34
P05.33 setting range: -100.0%
–100.0%
P05.34 setting range: P05.32
–10.00V
P05.35 setting range: -100.0%
–100.0%
2.00V
○
P05.33
Corresponding
setting of P1 lower
limit
0.0%
○
P05.34
P1 upper limit
10.00V
○
P05.35
Corresponding
setting of P1 upper
limit
100.0%
○
P05.36
P1 input filter time 0.000s
–10.000s
0.200s
○
P05.37
PT1 lower limit
Corresponding setting of the upper and lower
limits are the percentage of temperature
calibration point within the total range. The
percentage of analog input voltage can be
derived from the linear relationship between
the limits and their corresponding settings.
Current
temperature
=
Corresponding
percentage × 160
℃
Note: When the factory setting is restored, the
value
of
P05.38/P05.40/P05.48/P05.50
remains unchanged.
P05.37
setting range: 0.00V
–
P05.39
P05.38
setting range: -100.0%
–100.0%
P05.39
setting range:
P05.37
–10.00V
P05.40
setting range: -100.0%
–100.0%
0.00V
○
P05.38
Corresponding
setting of PT1 lower
limit
12.5%
○
P05.39
PT1 upper limit
10.00V
○
P05.40
Corresponding
setting of PT1 upper
limit
75.0%
○