Goodrive300-01 inverter for air compressor Communication protocol
-87-
Function instruction
Address
definition
Data meaning instruction
R/W
characteristic
100.0% of the rated current of the
motor)
2009H
Special control command word
Bit0~1:=00:motor 1 =01:motor 2
=10:motor 3 =11:motor 4
Bit2:=1 torque control
=0: speed control
Bit3: =1 power consumption clear
=0: do not clear power
consumption
Bit4: =1 pre-exciting =0:
pre-exciting prohibited
Bit5: =1 DC braking =0: DC
braking prohibited
W/R
200AH
Virtual input terminal command , range:
0x000~0x1FF
W/R
200BH
Virtual output terminal command ,
range: 0x00~0x0F
W/R
200CH
Voltage setting value(specific for V/F
separation)
(0~1000, 1000 corresponds to the
100.0% of the rated voltage of the
motor)
W/R
200DH
AO output setting value 1
(-1000~1000, 1000 corresponds to
100.0%)
W/R
200EH
AO output setting value 2
(-1000~1000, 1000 corresponds to
100.0%)
W/R
200FH
BIT0:=1 Clear the working time of part 1
=0: invalid
BIT1:=1 Clear the working time of part 2
=0: invalid
BIT2:=1 Clear the working time of part 3
=0: invalid
BIT4:=1 Clear the working time of part 5
=0: invalid
BIT5=1 Clear the working time of the
device
W/R