Goodrive300-01 inverter for air compressor Function parameters
-49-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
BIT13: pulse counter value
BIT14: length value
BIT15: PLC and the current step in multi-step speed
P07.06
Parameters
selection 2 for
running state
0x0000~0xFFFF
BIT0: AI1 (V on)
BIT1: AI2 (V on)
BIT2: AI3 (V on)
BIT3: HDI frequency
BIT4: motor overload percentage (% on)
BIT5: the inverter overload percentage (% on)
BIT6: ramp frequency reference (Hz on)
BIT7: linear speed
BIT8: AC inlet current (A on)
BIT9~15: reserved
0x0000
○
P07.07
Parameters for
stopping state
0x0000~0xFFFF
BIT0: set frequency (Hz on, frequency flickering
slowly)
BIT1: bus voltage (V on)
BIT2: input terminals state
BIT3: output terminals state
BIT4: PID reference (% flickering)
BIT5: PID feedback value (% on)
BIT6: torque set value (% on)
BIT7: AI1 (V on)
BIT8: AI2 (V on)
BIT9: AI3 (V on)
BIT10: HDI frequency
BIT11: PLC and the current step in multi-step speed
BIT12: pulse counter value
BIT13: length value
BIT14~BIT15: reserved
0x00FF
○
P07.08
Frequency
coefficient
0.01~10.00
Displayed frequency=running frequency*P07.08
1.00
○
P07.09
Rotation speed
coefficient
0.1~999.9%
Mechanical rotation speed =120*displayed running
frequency×P07.09/motor pole pairs
100.0%
○
P07.10
Linear speed
coefficient
0.1~999.9%
Linear speed= Mechanical rotation speed×P07.10
1.0%
○
P07.11
Rectifier bridge -20.0~120.0°C
●