Goodrive300-01 inverter for air compressor Communication protocol
-89-
Function instruction
Address
definition
Data meaning instruction
R/W
characteristic
inverter
Operation frequency
3000H
Compatible
with
communication
address of CHF100A, CHV100
R
Setting frequency
3001H
R
Bus voltage
3002H
R
Output voltage
3003H
R
Output current
3004H
R
Operation speed
3005H
R
Output power
3006H
R
Output torque
3007H
R
Close loop setting
3008H
R
Close loop feedback
3009H
R
Closed-loop setting
3008H
R
Closed-loop feedback
3009H
R
Input IO state
300AH
R
Input IO state
300BH
R
AI 1
300CH
R
AI 2
300DH
R
AI 3
300EH
R
AI 4
300FH
R
Read high speed pulse 1 input
3010H
R
Read high speed pulse 2 input
3011H
R
Read current step number of
the multi-step speed
3012H
R
External length value
3013H
R
External counting value
3014H
R
Torque setting value
3015H
R
Inverter identification code
3016H
R
Fault code
5000H
R
A.2.5 Fault message response
Code
Name
Meaning
01H
Illegal command
The command from master cannot be executed. The reason maybe:
1. This command is only for new version and this version cannot
realize.
2. Slave is in fault state and cannot execute it.
02H Illegal data address.
Some of the operation addresses are invalid or not allowed to
access. Especially the combination of the register and the
transmitting bytes are invalid.
03H
Illegal value
When there are invalid data in the message framed received by