Goodrive300-01 inverter for air compressor Commissioning guidelines
-82-
Chapter 4 Commissioning guidelines
4.1 Commissioning procedures for integrated system
4.1.1 Master inverter commissioning
1. Connect the wires according to the wiring diagram of the system. Before commissioning,
disconnect 24V power of the touch screen. Then ensure that the wiring is correct and the ground
wires are in good connection (including the grounding of the inverter and the cover).
Note: Pressure, temperature and fan speed control signals are current signals which are selected by
corresponding analog input and output terminals.
2. P00.18=1, restore to the factory default state. Set P00.03 according to the parameter settings of
the motor, then input the parameters of the motor and start motor autotuning.
Note: If there is no motor rated current on the name plate of the synchronous motor, set P02.19 to
inverter rated current or the default value.
参数自学习
电机类型
P02.00=1
P02.00=0
输入电机铭牌
(
P02.15~P02.19
)
输入电机铭牌
(
P02.01~P02.05
)
设置参数自学习方式
P00.15=2
(
静止自学习
)
按“
RUN
”键开始
自学习
自学习结束
同步电机
异步电机
3. Press QUICK/JOG for jogging and check the direction. If the direction is incorrect, change the
wiring of the motor.
4. Set P01.15 to 25.00Hz, and adjust the control parameters of the motor (current loop mainly).
P03.09 will be different in different motor power. Refer to P03.09 and P03.10 configuration table for
detailed function parameter instructions.
4.1.2 Fan commissioning
1. Connect the wires according to the wiring diagram of the system and check whether the wiring is
correct. Note: The fan speed control signals are 0-20mA current signals, so pay attention to jumper
selection for the terminals.
2. P00.18=1, restore to the factory default state, then input the parameters of the motor, press
QUICK/JOG for jogging and check the direction. If the direction is incorrect, change the motor wiring.
4.1.3 System commissioning
1. Connect the power of the touch screen and wait for the start-up of the system.
2. Enter into the interface of system configuration, set the parameters, including pressure sensor,