Goodrive300-01 inverter for air compressor Product overview
-10-
Name
Instruction
PE
Grounding terminal, PE can be short circuited with GND by J6. Please note that
PE is not short circuited with GND by default.
PW
Provide the input switch working power supply from external to internal
Voltage range: 12~24V
24V
The inverter provides the power supply for users with a maximum output
current 200mA
COM
+24V common terminal
S1
Switch input 1
1. Internal impedance:
3.3kΩ
2. 12~30V voltage input is available
3. The terminal is the dual-direction input terminal
supporting both NPN and PNP.
4. Max input frequency: 1kHz
5. All are programmable digital input terminals. Users
can set the terminal function through function codes.
S2
Switch input 2
S3
Switch input 3
S4
Switch input 4
S5
Switch input 5
S6
Switch input 6
S7
Switch input 7
S8
Switch input 8
HDI
Besides S1~S8, this terminal can be used as high frequency input channel
Max. input frequency: 50kHz
COM
+24Vcommon terminal
485+
485 communication interface and 485 differential signal interface
If it is the standard 485 communication interface, please use the twisted pair or
shield cable.
485-
PE1
485 communication shielded connection terminal. Select to connect shielded
layer to PE or isolate CGND by jumper J7.