Goodrive300-01 inverter for air compressor Function parameters
-79-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
P18.23
Counting period of
PID temperature
(Ts)
0.0~10.0s
2.0s
○
P18.24
Gain coefficient
(Kp)
0.0~100.0
18.0
○
P18.25
Convergence
coefficient (K)
0.00~1.00
0.12
○
P18.26
PID temperature
upper limit
0.00~100.00%
100.00%
○
P18.27
PID temperature
lower limit
0.00~100.00%
0.00%
○
P18.28
Pt100 temperature
compensation
-10.0~10.0°C
0.0°C
○
P18.29
compensation
coefficient of
Pt100 temperature
0.0~200.0%
100.0%
○
P18.30
Upper-limit
frequency
decreasing
pressure
0.00~ P18.04
When the current pressure is larger than the value,
the upper-limit frequency will decrease.
0.70Mpa
○
P18.31
Upper-limit
frequency
decreasing ratio
0.00Hz~10.00Hz
When the current pressure is larger than P18.30,
increase
0.01Mpa,
corresponding
upper-limit
frequency reduction.
0.00Hz
○
P19 Group State group for air compressor
P19.00
Set time for
maintenance of
component 1
0~65535h
Pre-alarm when the accumulated service time of
component 1 exceeds the set value; pre-alarm is
invalid when the set value=0.
0
●
P19.01
Set time for
maintenance of
component 2
0~65535h
Pre-alarm when the accumulated service time of
component 2 exceeds the set value; pre-alarm is
invalid when the set value=0.
0
●
P19.02
Set time for
maintenance of
component 3
0~65535h
Pre-alarm when the accumulated service time of
component 3 exceeds the set value; pre-alarm is
invalid when the set value=0.
0
●
P19.03
Set time for
0~65535h
0
●