Goodrive300-01 inverter for air compressor Function parameters
-30-
Function
code
Name
Detailed instruction of parameters
Default
value
Modif
y
coefficient P
parameter of the current loop which affects the
dynamic response speed and control accuracy
directly. Generally, users do not need to change
the default value.
2 Only apply to sensorless vector control mode 0
(P00.00=0).
The setting range: 0~65535
P03.09 value
(reference only)
P03.10 value
(reference only)
Motor power
2000
1000
7.5~22kW
2500
1500
30~37kW
3000
1500
45~90kW
3500
2000
110~132kW
4000
2000
160~200 kW
P03.10
Current loop
integral coefficient
1
1000
○
P03.11
Torque setting
This parameter is used to enable the torque control
mode and set the torque.
0:Torque control is invalid
1:Keypad (P03.12)
2: AI1
3: AI2
4: AI3
5:Pulse frequency HDI
6:Multi-step
7:MODBUS communication
8:Reserved
9:Reserved
10:Reserved
Note: Setting modes 2~10, 100% corresponds to
three times of motor rated current.
0
○
P03.12
Keypad setting
torque
The setting range: -300.0%~300.0% (motor rated
current)
50.0%
○
P03.13
Torque reference
filter time
0.000~10.000s
0. 010s
○
P03.14
Upper frequency
source of FWD
rotation in torque
control
0:Keypad (P03.16 sets P03.14, P03.17 sets P03.15)
1: AI1
2: AI2
3: AI3
4:Pulse frequency HDI
5:Multi-step
0
○
P03.15 Upper frequency
0
○