51
ASSEMBLY AND INSTALLATION
inVENTer
®
iV14R/iV14V ventilation system
•
Installation and operating instructions
TIP
Connect the ventilation unit initially in extract air mode (locking screws visible). This makes it
easier to test that the ventilation unit is working.
Ö
Ö
The reversible fan is connected to the controller.
iV14V ventilation system
Requirements:
Weather protection hood is itted
.
►
Remove the protective disc from the wall
sleeve.
►
Insert the thermal accumulator insert (1) into
the wall sleeve (2) from the interior.
Make sure that
the fan points into the interior.
Make sure that
the controller cable (3)
protrudes into the interior.
2
1
3
►
Turn the handle (7) to the top and clip it over
the corner of the fan (8).
7
8
►
Plug the connector (9) into the green socket
(10) on the plug connector of fan bus (11).
Make sure that
the locking screws on the
connector are pointing up.
Ö
Ö
Extract air mode is selected.
10
11
9