45
ASSEMBLY AND INSTALLATION
inVENTer
®
iV14R/iV14V ventilation system
•
Installation and operating instructions
Fitting sealing tapes to wall sleeve R-D204
Requirements:
Exterior wall inished and level and the wall sleeve is itted.
Ö
Ö
The sealing tapes on the wall sleeve V-177x177 for weather protection hood 09 are itted.
►
Remove the protective disc (21) from the wall
sleeve (20) from the exterior wall side.
2
1
►
Apply the foam strip, 220 mm x 50 mm, (23)
on the exterior wall side in the lower area of
the wall sleeve (22).
Make sure that
the foam strip (23) protrudes
outwards by 35 mm.
►
Cut into the foam strip (23) from the side using
a suitable tool.
►
Press the foam strip (23) down onto the
façade.
3
4
35
►
Afix the joint tape, 380 mm x 15 mm, (24) on
the exterior wall side in the upper area of the
wall sleeve.
Make sure that
the joint tape (24) does not
protrude over the inner edge of the wall sleeve
opening (25).
5
6
►
Apply the sealing tape, 9 mm, (26) all round
the front side of the wall sleeve.
7