43
ASSEMBLY AND INSTALLATION
inVENTer
®
iV14R/iV14V ventilation system
•
Installation and operating instructions
5.8
Fitting weather protection hood 09
NOTE
Installation on an uninished exterior wall.
Risk of damage to the exterior wall!
► Only install the weather protection hood once the exterior wall is inished and completely
hardened.
NOTE
Algae build-up around the weather protection hood:
Discolouration of the façade!
► Afix sealing tape all round prior to installing the weather protection hood base plate.
►
Carry out a biocide/water-repellent pretreatment on the render around the weather protection
hood in vulnerable areas (Please ask your planner for further information!).
NOTE
Penetration of condensate.
Risk of damage to masonry/the exterior wall!
► Fit sealing tape on the exterior wall side.
TIP
Fit the sealing tape only immediately prior to installing the weather protection hood. This prevents
the complete swelling of the sealing tape which makes the installation easier.
Fitting sealing tapes to wall sleeve R-D204
Requirements:
Exterior wall inished and level.
Wall sleeve is itted.
►
Remove the protective disc (2) from the wall
sleeve (1) from the exterior wall side.
1
2