71
OPERATION
inVENTer
®
iV14R/iV14V ventilation system
•
Installation and operating instructions
Removing the thermal accumulator insert
Requirement:
The reversible fan is switched off at the controller.
The inner cover panel is removed (see section 6.2).
Dust ilter is removed (see section 6.3)
.
TIP
For inner covers V-220x200 and Flair V-233x233 removal of the base plate is not necessary.
TIP
Before removing, mark the alignment of the green controller connector. This avoids the fan
running in the wrong direction when reconnected.
Ö
Ö
The thermal accumulator insert is removed.
►
Loosen the screws (1) using the hex key
provided.
►
Remove the inner cover base plate (2) from
the interior wall.
Ö
Ö
Base plate is removed.
1
2
►
Remove the thermal accumulator insert (5) by
the handle (6).
6
5
►
Mark the alignment of the controller
connector (4) (green arrow).
►
Remove the controller connector (4).
►
Detach the handle (3) from the corners of the
fan.
4
3