ASSEMBLY AND INSTALLATION
inVENTer
®
iV14R/iV14V ventilation system
•
Installation and operating instructions
NOTE
Incorrect wiring/electrical connection.
Risk of damage to the fan motor!
►
Connect the ventilation unit to the power supply via a controller.
TIP
Make sure that the wire colour sequence is correct to ensure that the fans start
(see section 4: Wiring/electrical connection ‒ Controller connector wiring).
TIP
Connect the ventilation unit initially in extract air mode (locking screws visible). This makes it
easier to test that the ventilation device is working.
Ö
Ö
Fan is connected to the controller.
►
Plug the connector (10) into the green socket
on the plug connector of fan bus (11).
Make sure that
the locking screws (9) on the
connector (10) are pointing up.
Ö
Ö
Extract air mode is selected.
9
11
10
►
Trim controller cable, three-wire, (6) to the wall
thickness you have calculated.
►
Pull the connector (4) out of the plug
connector of fan bus (5).
►
Fasten the controller cable (6) to the
connector (4).
4
6
5
►
Turn the handle (8) to the top and clip it over
the corner of the fan (7).
8
7