TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Nugget
Co de 39
6-10
Problems While Configuring the Terminal (continued)
Problem
Solution
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error.
SOM is set. You must also set
EOM.
Configuration was not updated.
You must configure a value for EOM before you can set SOM or
disable SOM. You need to change the value of SOM. Choose Serial
Port from the Communications Menu.
The configurable serial protocol (CSP) uses EOM to determine the
serial communications mode. When EOM is disabled, the terminal
communicates in Character mode. When EOM is enabled, the
terminal communicates in Frame mode. To use Frame mode, you need
to set EOM first. Next, configure Handshake, Configuration
Commands Via Serial Port, LRC, SOM, and then Poll.
For help, see “Using Serial Communications on the Terminals” in
Chapter 4.
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error.
SOM cannot equal EOM.
Configuration was not updated.
SOM cannot equal the same value that is set for EOM. You cannot set
SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll,
RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change
the value of SOM. Choose Serial Port from the Communications
Menu.
For help, see “Start of Message (SOM)” in Chapter 9.
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error.
EOM #1 cannot equal EOM #2.
Configuration was not updated.
EOM can be one or two ASCII characters, but you cannot set the first
and second character to the same character. Also, you cannot set EOM
to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES
(EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the
value of EOM #1 or #2. Choose Serial Port from the Communications
Menu.
For help, see “End of Message (EOM)” in Chapter 9.
You are configuring the serial port and see
this error message when exiting the
Configuration Menu:
Serial port configuration
error. DLE, XON, XOFF are not
valid values for either SOM or
EOM.
Configuration was not updated.
You cannot set EOM or SOM to any of these values: AFF (ACK),
DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or
XON. You need to change the value of EOM or SOM. Choose Serial
Port from the Communications Menu.
For help, see “End of Message (EOM)” or “Start of Message (SOM)”
in Chapter 9.
Summary of Contents for Trakker Antares 2420
Page 1: ...TRAKKERAntares 2420and2425 Hand HeldTerminal P N 064024 006 User s Manual...
Page 15: ...nuggetf code39 Contents xv Glossary Index G I...
Page 16: ...xvi...
Page 24: ...xxiv...
Page 25: ...nuggetf code39 Getting Started 1...
Page 26: ...1 2...
Page 60: ...1 36...
Page 61: ...Learning How to Use the Terminal 2...
Page 62: ...2 2...
Page 103: ...Co de 39 Nugget Configuring the Terminal 3...
Page 104: ...Co de 39 Nugget 3 2...
Page 134: ...3 32...
Page 135: ...Operating the Terminal in a Network 4...
Page 136: ...4 2...
Page 173: ...Using Custom Applications 5...
Page 174: ...5 2...
Page 193: ...Troubleshooting 6...
Page 194: ...6 2...
Page 219: ...Running Diagnostics 7...
Page 220: ...7 2...
Page 243: ...Reader Command Reference 8...
Page 244: ...8 2...
Page 268: ...8 26...
Page 269: ...Configuration Command Reference 9...
Page 270: ...9 2...
Page 389: ...Terminal Specifications A...
Page 390: ...A 2...
Page 404: ...A 16...
Page 405: ...Full ASCII Charts B...
Page 406: ...B 2...
Page 415: ...International Character Support C...
Page 416: ...C 2...
Page 427: ...Using the Default Applications D...
Page 428: ...D 2...
Page 438: ...D 12...
Page 439: ...Glossary G...
Page 440: ...G 2...
Page 463: ...Index I...
Page 464: ...I 2...
Page 480: ...I 18...