If you want a protocol handler to always be present, you can include the
command line in your AUTOEXEC.BAT file. However, this requires more
memory to operate the JANUS 2050.
Loading/Unloading Protocol Handlers With IRL Desktop or
Communications Manager
You can load a protocol handler for a designated port when you execute the
IRL Desktop or the Communications Manager utility. When you exit the
program, the protocol handler is unloaded. To load a protocol handler when
executing IRL Desktop or Communications Manager, you enter the following
command at the DOS prompt:
{
application} -[{port}{ph}]
where:
application is the application you are executing. For IRL Desktop, enter irl. For
the Communications Manager, enter cmgr
.
port indicates the port for which you are loading the protocol handler. To load
the protocol handler for COM1, enter 1.
ph is the notation for the protocol handler you want to load. For the Intermec
protocol handler, enter i. For the PC Standard protocol handler, enter p.
For example, to load the Intermec protocol handler on COM1 and execute the
IRL Desktop, you enter the following command at the JANUS 2050 DOS
prompt:
irl -1i
Specifying a Value for the FIFO Control Register
The First In First Out (FIFO) control register contains a hex value that controls
the Universal Asynchronous Receiver/Transmitter (UART) buffer. For
example, the FIFO control register can enable UART 16x550 mode and require
the buffer to receive four bytes of data before generating a receive interrupt.
If you turn off your JANUS device while running a communications
application, the device cannot save the contents of the UART FIFO control
register. When you turn the device back on, the device sets the FIFO control
register to its default value, 0 hex, unless you have already specified a value
that the device can use to restore the FIFO control register. You should specify
another value if the default is not appropriate for the JANUS 2050 UART FIFO
control register.
Summary of Contents for Janus 2050
Page 1: ...P N 065716 001 User s Manual JANUS 2050 Vehicle MountComputer 4MB ...
Page 2: ...P N 065716 001 User s Manual JANUS 2050 Vehicle MountComputer 4MB ...
Page 21: ......
Page 22: ...Getting Started 1 ...
Page 23: ......
Page 40: ...Operating the JANUS 2050 2 ...
Page 41: ......
Page 64: ...Using the JANUS 2050 Software 3 ...
Page 65: ......
Page 96: ...Configuring the JANUS 2050 4 ...
Page 97: ......
Page 111: ...39 39 nugget nugget A A ...
Page 112: ...Using PC Cards 5 ...
Page 113: ......
Page 132: ...Communicating With the JANUS 2050 6 ...
Page 133: ......
Page 164: ...Working With IRL 7 ...
Page 165: ......
Page 183: ......
Page 184: ...code 39 nugget helcond Troubleshooting 8 ...
Page 185: ......
Page 210: ...Command Reference 9 ...
Page 211: ......
Page 219: ......
Page 220: ...Configuration Commands 10 ...
Page 221: ......
Page 316: ...Advanced Operations 11 ...
Page 317: ......
Page 323: ...39 39 nugget nugget A A ...
Page 324: ...Configuration and Full ASCII Charts A ...
Page 325: ......
Page 353: ...39 39 nugget nugget A A ...
Page 354: ...Specifications B ...
Page 355: ......
Page 365: ...39 nugget A ...
Page 366: ...Software Utility Reference C ...
Page 367: ......
Page 381: ...39 nugget A ...
Page 382: ...Glossary G ...
Page 383: ......
Page 406: ...Index I ...
Page 407: ......