Chapter 6: Command line mode
NS3552-8P-2S-V2 User Manual
361
Security Switch SNMP Trap Link-up
Description:
Set or show the port link-up and link-down trap mode.
Syntax:
Security Switch SNMP Trap Link-up [enable|disable]
Parameters:
enable
: Enable SNMP trap link-up and link-down
disable
: Disable SNMP trap link-up and link-down
(default: Show SNMP trap link-up and link-down mode)
Default Setting:
enable
Example:
Disable SNMP trap link-up
NS3552-8P-2S-V2:/>
security
switch
snmp
trap link-up disable
Security Switch SNMP Trap Inform Mode
Description:
Set or show the SNMP trap inform mode.
Syntax:
Security Switch SNMP Trap Inform Mode [enable|disable]
Parameters:
enable
: Enable SNMP trap inform
disable
: Disable SNMP trap inform
(default: Show SNMP inform mode)
Default Setting:
enable
Example:
Disable SNMP trap inform mode.
NS3552-8P-2S-V2:/>
security
switch
snmp
trap inform mode disable
Security Switch SNMP Trap Inform Timeout
Description:
Set or show the SNMP trap inform timeout (usecs).
Syntax:
Security Switch SNMP Trap Inform Timeout [<timeout>]
Parameters:
<timeout>
: SNMP trap inform timeout (0-2147 seconds)
(default: Show SNMP trap inform timeout)
Default Setting:
1
Example:
Set SNMP trap inform timeout in 20sec.
NS3552-8P-2S-V2:/>
security
switch
snmp
trap inform timeout 20
Summary of Contents for NS3552-8P-2S-V2
Page 1: ...NS3552 8P 2S V2 User Manual P N 1073552 EN REV B ISS 25JAN19 ...
Page 41: ...Chapter 3 Switch management NS3552 8P 2S V2 User Manual 39 ...
Page 73: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 71 ...
Page 147: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 145 ...
Page 511: ......