Chapter 4: Web configuration
282
NS3552-8P-2S-V2 User Manual
Cable diagnostics performs tests on copper cables. These functions have the ability to
identify the cable length and operating conditions, and to isolate a variety of common
faults that can occur on the Cat5 twisted-pair cabling. There might be two states, which
are as follows:
• If the link is established on the twisted-pair interface in 1000BASE-T mode, the
cable diagnostics can run without disruption of the link or of any data transfer. A
1000Base-T Laptop/PC is preferred for testing the cable diagnostic function.
• If the link is established in 100BASE-TX or 10BASE-T, the cable diagnostics cause
the link to drop while the diagnostics are running. This may require the following
steps:
• Select the
Auto Refresh
check box.
• Click the
Fresh
button 45 seconds after the cable diagnostic function has
started.
After the diagnostics are finished, the link is re-established and the following functions
are available.
• Coupling between cable pairs
• Cable pair termination
• Cable length
The page includes the following fields:
Object
Description
Port
The port where you are requesting cable diagnostics.
Cable Status
Port
: Port number.
Pair
: The status of the cable pair.
Length
: The length (in meters) of the cable pair. The resolution is 3 meters
Buttons
• Click
Start
to run the diagnostics.
Summary of Contents for NS3552-8P-2S-V2
Page 1: ...NS3552 8P 2S V2 User Manual P N 1073552 EN REV B ISS 25JAN19 ...
Page 41: ...Chapter 3 Switch management NS3552 8P 2S V2 User Manual 39 ...
Page 73: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 71 ...
Page 147: ...Chapter 4 Web configuration NS3552 8P 2S V2 User Manual 145 ...
Page 511: ......