Figure 1: 60-660-8OM Quik Bridge® Output Module 

Figure 2: Main Quik Bridge® components 

(1) Tamper 

switch 

(2) CON4 

Temporary 

connection for the keypad. 
Remove the keypad after 
programming. 

(3)  NX bus (power and data) 

 

(4)  Quik Bridge® outputs 
(5) LEDs 

 

 

 

Figure 3: Quik Bridge® outputs 

Figure 4: Receiver LEDs 

(1) Power 

 

(2) Low 

battery 

 (3) 

Supervisory 

 

(4) Zone 

 

Figure 5: Removing the Quik Bridge® cover and installing the 
cover screws 

(1)  Quik Bridge® cover 
(2)  Screw holes for securing cover 

Figure 6: Base mounting hole locations 

(1) Mounting 

holes 

(2) Lower 

right 

latch 

Figure 7: Connecting the Quik Bridge® to the keypad and receiver

(1)  RF Quik Bridge® 
(2) RF 

Receiver 

(3) NX-148 

keypad 

 

(4)  Panel +12 V 
(5) Panel 

GND 

Figure 8: Connecting power to the Quik Bridge® 

(1)  To panel's 12 V supply 
 

 

 
 

Figure 9: Wiring diagrams 

(A) Wiring 

diagram 

for supervised loop 

(B)  Wiring diagram for non-supervised loop 
(C)  Wiring diagram when using a relay 
(D)  Wiring diagram for the NX V3 range of panels 

(1) Zone 

(2) Return 
(3) Panel 

GND 

(4)  Panel + 12 V 
(5) EOL 

resistors 

 

 (6) 

N/O 

(7) COM 
(8) N/C 
(9) Coil 
(10)  12 VDC relay - coil 

resistance must be at least 
300 Ohms  

Figure 10: Example of a configuration 

(1)  Any control panel with 

negative common ground 

(2)  60-660-8OM Quik Bridge® - 

output module 

(3)  Keypad to be used for 

programming (remove 
afterwards) 

 

(4)  NX Wireless Receiver 
(5) RF 

Transmitters 

Description 

The Quik Bridge® Output Module combined with the NX 
wireless receiver allows 8 wireless transmitters to be used on 
the wired inputs of a control panel. It can be programmed to 
reflect either the state of an individual transmitter or a selection 
of transmitters. The Quik Bridge® also has 8 LEDs that display 
the current state of a programmed output. 

The Quik Bridge® features the following: 

• 

8 programmable zone outputs (N/C or N/O). These can 
show tamper indication for all zones, receiver 
communication trouble/ jam for the NX Receiver and box 
tamper for the NX Receiver or Quik Bridge® output 
module. 

• 

8 zone LEDs, which indicate zone openings and closings. 

• 

NX bus to connect the Quik Bridge®  with the NX Receiver 
and with the NX-148 LCD Keypad. The LCD keypad is 
temporarily used for programming purposes, and can be 
disconnected after completion of the Quik Bridge®  
programming. The control panel can provide power to the 
Quik Bridge®. Do NOT wire the DATA line back to the 
control panel as this might damage your control panel. 

• 

2 trouble LEDs, which indicate sensor low battery, 
supervisory conditions, tamper-trouble conditions and a 
power LED to indicate power going to the Quik Bridge®. 

• 

On-board EEPROM that stores sensor IDs and 
programming information in non-volatile memory, if power 
is removed. 

Transmitter Capability 

All current Learn Mode™ transmitters (868.6 MHz and 
433 MHz). 

Control Panel Compatibility 

The Quik Bridge® is compatible with control panels designed 
with hardwire loops where the loop negative is ground, 
otherwise known as a common-loop ground. 

The loop receiver is not directly compatible with powered loops 
(2-wire smoke detector loops and glass break detector loops). 
If the loop on the control panel can power a device, it must not 
be connected directly to the loop receiver. Instead, a relay is 
required when connecting to powered loops. 

Compatibility Testing 

Typically, hardwire loops have the negative (-) side of the loop 
common with the ground. If this is true and the loop is non-
powered, the loop should be compatible with the receiver. 

Although most control panels are compatible with the receiver 
open collector outputs, each loop should be tested for 
compatibility before connecting Quik Bridge® outputs to the 
control panel loop inputs. If the Quik Bridge® is not directly 
compatible with a control panel loop, a relay can be used to 
establish compatibility. 

To check if the negative side of the loop is common to the 
control panel ground, perform the following test: 

1.  Turn off or remove the control panel power and disconnect 

the back-up battery. 

2.  Use an Ohm meter and measure the resistance between 

the negative side of the loop and panel ground. If the 
resistance is zero or close to zero, this loop should be 
compatible with the loop receiver. If the resistance is not 
zero, a relay is required for this loop. 

Perform this compatibility test for all loops that are to be 
connected to the Quik Bridge. 

Summary of Contents for 60-660-8OM Quik Bridge

Page 1: ...2013 UTC Fire Security All rights reserved 1 27 P N 466 2488 REV A ISS 02JUL13 60 660 8OM Quik Bridge Output Module Installation Sheet EN FR IT NL 1 2 3 4 5 6...

Page 2: ...2 27 P N 466 2488 REV A ISS 02JUL13 7 8 9 10 60 660 8OM 4 3 5 6 7 8 NX Receiver DATA COM POS A B D C 3K3 3K3...

Page 3: ...Quik Bridge with the NX Receiver and with the NX 148 LCD Keypad The LCD keypad is temporarily used for programming purposes and can be disconnected after completion of the Quik Bridge programming The...

Page 4: ...s turn on for zones that are open in alarm Zone LEDs remain off for zones that are closed or not used Condition 2 To diagnose transmitter supervisory 868 6 MHz The supervisory LED indicates when 1 or...

Page 5: ...Open the NX Receiver and NX 148 LCD Keypad 2 Wire the data common ground and positive lines for power and programming to the Quik Bridge The control panel provides power to the Quik Bridge Do NOT wir...

Page 6: ...ss 8 followed by 9713 3 Press 32 to program the RF Receiver module 4 Press 910 to go to location 910 This loads the factory defaults for the Receiver The keypad beeps 3 times indicating that loading i...

Page 7: ...event 2 Output 6 time 12 1 Output 6 Transmitter selection 2 Output 6 Special Setting 13 1 Output 7 event 2 Output 7 time 14 1 Output 7 Transmitter selection 2 Output 7 Special Setting 15 1 Output 8 e...

Page 8: ...Specifications Compatibility Control panels with hardwire loops Power requirements 10 14 VDC Current draw 60 mA maximum Open collector outputs 1 8 B S maximum applied voltage 16 VDC maximum sink curr...

Page 9: ...lit des panneaux de commande Le Quik Bridge est compatible avec les panneaux de commande con us avec des boucles c bl es o le n gatif de la boucle est la terre masse de boucle commune Le r cepteur bou...

Page 10: ...res de supervision RF pour la Belgique et les Pays Bas Lorsqu une condition de supervision existe le t moin de supervision clignote en synchronisation avec au moins 1 t moin de zone V rifiez l metteur...

Page 11: ...eau mais la saisie de donn es au panneau doit tre d connect e Raccordement du r cepteur NX et du clavier LCD NX 148 au Quik Bridge 1 Ouvrez le r cepteur NX et le clavier LCD NX 148 2 C blez le fil de...

Page 12: ...que la zone de d part est donc 1 Appuyez sur pour quitter l emplacement 6 Appuyez sur 0 1 pour enregistrer l metteur 1 Ouvrez l interrupteur de d tection des fraudes sur l metteur et le clavier devra...

Page 13: ...sion sur le bouton du porte cl s active la sortie Programmation du Quik Bridge Le Tableau 7 indique les 17 emplacements qui peuvent tre programm s sur le Quik Bridge Tableau 7 Emplacements et segments...

Page 14: ...r r gler les metteurs 2 8 afin qu ils activent la sortie 2 emplacement 4 segment 1 2 8 Exemple R glage Pour r gler les 8 metteurs afin qu ils activent la sortie 8 emplacement 16 segment 1 1 2 3 4 5 6...

Page 15: ...ve essere almeno di 300 Ohm Figura 10 Configurazione di esempio 1 Qualsiasi centrale di controllo con riferimento comune a negativo 2 60 660 8OM Quik Bridge modulo di uscita 3 Tastiera da utilizzare p...

Page 16: ...uscite possono essere aperte impedenza elevata o chiuse cortocircuitate a negativo e configurate in modo da risultare normalmente chiuse N C o normalmente aperte N A mediante la programmazione Ciascun...

Page 17: ...a dei circuiti vedere figura 6 3 Rimuovere la scheda dei circuiti estraendola dai 2 fermi superiori e metterla da parte 4 Posizionare la base sulla superficie di montaggio e contrassegnare i 3 fori di...

Page 18: ...mettere i dati e passare al segmento successivo Premere per lasciare la locazione prima dell ultimo segmento 6 Una volta programmato l ultimo segmento della locazione premere il tasto per uscire dalla...

Page 19: ...120 finestra di supervisione lunga 20 finestra di supervisione corta Belgio 120 finestra di supervision trasmettitori antincendio 120 finestra di supervision trasmettitori antincendio 20 finestra di...

Page 20: ...modulo uscite o interferenze 24 Riservato 25 Riservato Tempo attivazione uscita Il valore per l impostazione del tempo attivazione compreso tra 0 e 255 minuti o secondi L unit di misura viene imposta...

Page 21: ...centri di raccolta preposti Per maggiori informazioni vedere ww recyclethis info Informazioni di contatto www utcfireandsecurity com o www interlogix com Per l assistenza clienti vedere http www inter...

Page 22: ...patibiliteit worden getest alvorens de Quik Bridge uitgangen te verbinden met de lusingangen van het controlepaneel Als de Quik Bridge niet rechtstreeks te gebruiken is met een lus van het controlepan...

Page 23: ...nchroon te knipperen met minstens 1 zone LED Controleer de overeenkomstige zonezender s op een sabotage of storingstatus De volgende tabel toont de LED aanduidingen bij alarm lage batterij controle en...

Page 24: ...databits Stappen 1 Om in de programmeerstand te gaan toetst u op 8 gevolgd door de programmeercode De standaard programmeercode is 9713 2 Voer het nummer van de module in gevolgd door Toets 0 om de Q...

Page 25: ...voor zender 4 voert u 4 in 4 In Locatie 1 Segment 1 zet u bit 1 uit om de zender te verwijderen 5 Toets vervolgens op om de instelling te bewaren en om het menu af te sluiten RF Supervisietijden voor...

Page 26: ...11 Afstandsbediening inschakelen 12 Afstandsbediening in of uitschakelen 13 Toets Gedeeltelijk In 14 Afstandsbediening exit 15 Gereserveerd 16 Gereserveerd 17 Gereserveerd 18 Toets optie 1 Optie 4 va...

Page 27: ...Te gebruiken met Controlepaneel met bedrade zone ingangen Voedingsvereisten 10 14 VDC Stroomafname max 60 mA Open Collectoruitgangen 1 8 B S maximale spanning 16 VDC maximale stroom 50 mA normaal 15...

Reviews: