MP73P+ : Battery charger/analyser
Operators Manual
11
Miscellaneous Unit Functions
11.1
Description Of Stop Codes
•
NO VALID DATA TO SHOW
This will not usually appear. It is used when the battery charger has been reset
and the previous end of charge or discharge results are requested.
•
BATTERY < TARGET VOLTS
Applies to
CAPACITY TEST TO 100%
mode only. it indicates that the battery
terminal voltage has reached the
Target Volts
setting this is a normal end of
test condition and the capacity figure will be valid.
•
CHARGE COMPLETED
Applies to all charge modes. It indicates that the
Charge Time
has been
reached, or in
CONSTANT VOLTAGE CHARGE
an indication that the
Min
Amps
point has been reached, in
CONSTANT CURRENT CHARGE
and
CELL
MONITOR CC CHARGE
that the
Target Voltage
has been met where no
Extra Time
was specified.
•
CAPACITY TEST COMPLETED
Applies to all capacity test modes. It indicates that the
Discharge Time
has
been reached, or in
CAPACITY TEST TARGET
an indication that the
Target
Voltage
has been met.
•
DISCHARGE COMPLETED
Applies to all discharge modes. It indicates that the Discharge Time has been
met.
•
OVERCHARGE VOLT REACHED
Applies to
CONSTANT CURRENT CHARGE
and
MULTI-STEP CHARGE
modes. It is an indication that the
Overcharge Volts
set point has been
reached.
•
BATTERY THRESHOLD AMPS
Applies to
CONSTANT VOLTAGE CHARGE
only and indicates that the charge
current has increased more than the
Amps Rise
threshold after the
Target
Volts
had been achieved indicating a potentially faulty battery.
•
STOPPED BY OPERATOR
Applies to all modes. Indicates that the charge or discharge operation was
stopped by the operator pressing the
‘CLR’
key.
•
BATTERY REV OR < 0.1V
Applies to all modes. Indicates that a battery voltage less that 0.1V has been
Doc: DWG1042-12-R18 MB73P+ Operators manual.odt
Page 54 of 64
Copyright Material of Intelligent Charging Limited © 2020
Printed On : 29/11/20